Ultra-Low-Voltage Frequency Synthesizer and Successive-Approximation Analog-to-Digital Converter for Biomedical Applications

個数:1
紙書籍版価格
¥22,524
  • 電子書籍
  • ポイントキャンペーン

Ultra-Low-Voltage Frequency Synthesizer and Successive-Approximation Analog-to-Digital Converter for Biomedical Applications

  • 著者名:Hung, Chung-Chih/Wang, Shih-Hsing
  • 価格 ¥17,201 (本体¥15,638)
  • Springer(2021/12/07発売)
  • 麗しの桜!Kinoppy 電子書籍・電子洋書 全点ポイント25倍キャンペーン(~3/29)
  • ポイント 3,900pt (実際に付与されるポイントはご注文内容確認画面でご確認下さい)
  • 言語:ENG
  • ISBN:9783030888442
  • eISBN:9783030888459

ファイル: /

Description

This book introduces the origin of biomedical signals and the operating principles behind them and introduces the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-power integrated circuits.

Both implantable and in-vitro medical signal detectors require two basic components to collect and transmit biomedical signals: an analog-to-digital converter and a frequency synthesizer because these measured biomedical signals are wirelessly transmitted to the relevant receiving unit. The core unit of wireless transmission is the frequency synthesizer, which provides a wide frequency range and stable frequency to demonstrate the quality and performance of the wireless transmitter. Therefore, the basic operating principle and model of the frequency synthesizer are introduced. We also show design examples and measurement results of a low-power low-voltage integer-N frequency synthesizer for biomedical applications. The detection of biomedical signals needs to be converted into digital signals by an analog-to-digital converter to facilitate subsequent signal processing and recognition. Therefore, the operating principle of the analog-to-digital converter is introduced. We also show implementation examples and measurement results of low-power low-voltage analog-to-digital converters for biomedical applications.

Table of Contents

​1. Introduction to biomedical signals and their applications.- 2. Low-power and low-voltage VLSI Circuit design Techniques for Biomedical Applications.- 3. Introduction of Frequency Synthesizer.- 4. A 0.35-V 240-μW Fast-Lock and Low-Phase-Noise frequency synthesizer for implantable biomedical applications.- 5. Introduction of ADC.- 6. A 0.3V 10b 3MS/s SAR ADC with comparator calibration and kickback noise reduction for biomedical applications.- 7. Summary.

最近チェックした商品